Milestone inspections
At 30 years—and as early as 25 years where local conditions warrant—qualifying buildings enter a recurring structural inspection cycle.

Florida building restoration
The report finds it.
We fix it.
We turn milestone inspection and SIRS findings into durable, expertly managed repairs.
Calculate your deadlineFlorida’s evolving building safety market
Florida Senate Bill 4-D and subsequent updates created a new standard for aging condominium and cooperative buildings. The inspection identifies the issue. The reserve study plans for it. C&S delivers the work.
At 30 years—and as early as 25 years where local conditions warrant—qualifying buildings enter a recurring structural inspection cycle.
Structural Integrity Reserve Studies evaluate critical components, remaining useful life, and funding needs on a ten-year cycle.
When reports call for repair, associations need a contractor who can plan access, coordinate with the design team, and execute the scope.
Compliance, made practical
The rules are simpler than they look. A qualifying building’s first milestone inspection lands on the 30th year after its Certificate of Occupancy — or the 25th year when the building sits within three miles of the coast, or your local ordinance calls for it sooner. After the first inspection, the cycle repeats every ten years.
Run your building below. It takes thirty seconds, and the answer shapes your budget, your reserve schedule, and your board calendar.
Deadline calculator
Enter your building’s details to see the milestone inspection deadline and renewal cadence that apply.
Phase 1 — Visual
A licensed engineer or architect examines the structure visually, reviewing prior reports and repair records. If the building shows no signs of substantial structural distress, Phase 1 is the end of the story.
Phase 2 — Testing
When distress appears, Phase 2 goes deeper — ground-penetrating radar, concrete core sampling, and ultrasonic testing — to establish whether the distress means structural damage that requires repair.
A Structural Integrity Reserve Study is mandatory for qualifying condominium and cooperative buildings and covers the components that hold the structure up: the roof, load-bearing walls, primary structural members, foundations, fireproofing, and waterproofing.
Remediation capabilities
A coordinated field partner for associations, property managers, engineers, and reserve specialists.
Spall repair, crack treatment, corrosion mitigation, and structural concrete remediation executed to the engineer’s repair documents.
Traffic coatings, sealants, exterior painting, and waterproofing systems that protect the envelope from Florida’s harsh coastal exposure.
Targeted roof, window, door, and exterior envelope work aligned with long-range SIRS repair and replacement planning.
Specialized access, temporary shoring, and field coordination to support investigation, testing, and safe remediation.
A clear path forward
We review the inspection report, SIRS priorities, repair documents, and building constraints.
Our team develops sequencing, access, resident communication, safety, and cost controls around the scope.
We execute the work in close coordination with the association, property manager, and engineer of record.
Closeout documentation and maintenance guidance help preserve the repair and support future planning.
Milestone deadlines, SIRS funding, and unit-owner pressure land on your desk. Bring us the report — we build the field plan around it and keep residents, budgets, and timelines aligned.
Start with your report
High-rise office, hospitality, and mixed-use assets carry the same structural clock. We scope facade and structural work to protect asset value, tenancy, and your capital plan.
Start with a walkthrough
Board readiness
C&S Restoration
Bring us your milestone findings, SIRS priorities, or active repair documents. We’ll help define the next move.
Start the conversation